Model 6013/6014
4-3 6015 JUNCTION BOX
The 6084 Junction Box is for terminating
thermocouples and other inputs.
The interior of the thermocouple junction box must be
at a uniform temperature to minimize temperature
differential between the thermocouple connections
and the temperature sensor. Therefore, it is important
that the cover be installed after connections are made
and that the grommet through which the cables enter
be sealed. It is also recommended that the junction
box be placed in a location that has the lowest
temperature variation. If temperature variations are
extreme, the junction box may be filled with Styrofoam
or similar insulating material to reduce air movement.
The layout of the terminal blocks in the junction box is
shown in the following diagram along with the terminal
signal assignments. Notice that channel 0 is
assigned to junction terminal block 1 in the lower left.
6084 Junction Box
The 6015 junction box has isothermal screw
terminals and a sensor that measures the
temperature of the terminations. Knowing the
temperature, PI660 software will remove the
temperature error introduced by connecting the
thermocouple wire to the copper measurement
circuit. The 6084 also has a circuit that causes
the measurement to exceed full scale if an input
opens and has a location for the user to install a
low-pass filter. The 6084 comes standard with 3
meters of cable for connecting to the 6013. Longer
cable length may be special ordered for remotely
locating thermocouple terminations. 1 meter of the
cable is used to up from routing through the cable
egress of the 6000 enclosure leaving 2 meters
useable outside enclosure.
6015
-
1 Thermocouple Input Circuit
Page view 0
1 2 3 4 5 6 ... 10 11

Summary of Contents

Page 1

Model 6013/6014 4-3 6015 JUNCTION BOX The 6084 Junction Box is for terminatingthermocouples and oth

Page 2

Model 6013/6014 LED and LED Off turn on and off the LED on the front of the channel card. This featur

Page 3 - 50-Pin Type D

Model 6013/6014 4-7.4 Filter The standard anti aliasing filter is a four-pole, Butterworth low pass with plug-in frequencyselec

Page 4 - 6013 Typical Inputs

Model 6013/6014 4-4 6081 SCREW TERMINAL ADAPTER The 6081 Screw Terminal Adapter is for makingconnecti

Page 5

Model 6013/6014 012301230123012301230123GuardGuardGuardGuard-In-In-In-In+In+In+In+In-Exc-Exc-Exc-Exc

Page 6

Model 6013/6014 +In-InGuardThermocouple+In-In+Exc-ExcEcomGuard+12/15-12/15ComDC LVDTOutOut+In-InGuardV

Page 7

Model 6013/6014 Guard+In-In+DC-DCDiffAmpGainCal(DAC)Filter+1MonitorMuxADCFIFOFIFOCh 1Ch 7AutoZero(DA

Page 8

Model 6013/6014 +In-InGuardIES or ICP TransducerAC Coupled+In-InGuardVoltage SignalAC or DC CoupledIES

Page 9

Model 6013/6014 Guard+In-In+DC-DCDiffAmpGainCal(DAC)Filter+1MonitorMuxADCFIFOFIFOCh 1Ch 7AutoZero(DA

Page 10

Model 6013/6014 +In-InGuardIES or ICP TransducerAC Coupled+In-InGuardVoltage SignalAC or DC CoupledIES

Page 11

Model 6013/6014 4-6.6 DC-Powered Transducers Like the 6013, the 6014 can supply DC power for operati

Comments to this Manuals

No comments