CAMPUS-RS CSU/DS-1AND CSU/DSX-1INTERFACE CARDSUSERMANUAL
Table of Contents x Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
Testing the System Using Loopback Tests 6-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 7-17TESTING THE SYSTEM(LOOPBACK TESTS)The Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Card
Testing the System (Loopback Tests) 7-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User ManualLocal to Local LoopbacksThe Local to Local loopba
Testing the System (Loopback Tests)Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 7-3CLEARING LOOPBACKSYou can clear a loopback test in
Testing the System (Loopback Tests) 7-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User ManualV.54 LOOPBACK SUPPORTThe Campus-RS CSU/DS-1 and C
Testing the System (Loopback Tests)Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 7-5
Testing the System (Loopback Tests) 7-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual A-1 ATECHNICAL REFERENCEThis chapter includes technical reference information about the C
A-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual PINOUTSThis section shows data port pinouts for the Campus-RS CSU/DS-1 and CSU/DSX-1
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual A-3 The following figure shows the pinouts on the CSU/DSX-1 card DB-15 connector. The pi
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 1-1 1ABOUT THE PRODUCTThe PairGain® Campus-HRS™ (HDSL Rate Selectable) CSU/DS-1 and CSU/D
A-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual CI AND NI CONFIGURATIONSANSI standard T1.403 defines the requirements for a DS1 meta
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual A-5 LCD MENU REFERENCEThe following illustration diagrams the LCD menu structure.CAMPUS
A-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Continued from previous pageCURRENT ALARMSHDSL LINK ALARMS CONFIG & STATUSALARMC
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual A-7 ASCII TERMINAL MENU REFERENCEThe following illustration diagrams the ASCII terminal
A-8 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual DS-1 Line LoopbackRemote Data Port toward Local Data PortDS-1 Payload LoopbackLocal
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual B-1 BABBREVIATIONS2B1Q 2 Binary, 1 QuarternaryAIS Alarm Indication Signal (a pattern of a
B-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual C-1 CTHE DOCUMENTATION SETThis table describes all the manuals and guides in the Campus-R
C-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual D-1 DTECHNICAL ASSISTANCEANDWARRANTYADC Customer Service Group provides expert pre-sales
About the Product 1-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual The front-panel LEDs on the chassis indicate the transmission stat
D-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual ADC Technical Assistance Center800.366.3891, extension 73223 or952.917.3223 Fax: 952
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Index-1 EINDEXAalarmshistoryASCII terminal 5-4 to 5-7, 5-10 to ...
Index-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual cancelling loopbacks ...6-3, 7-3checksum informationASCII term
Index-3 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual ASCII terminal ...4-18, 5-16LCD ...
Index-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual LCD ... 3-19See also V.35 loopback supportLOS alar
Index-5 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual LCD ... 3-11software versionASCII termina
Index-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
ADC DSL Systems, Inc.14402 Franklin AvenueTustin, CA 92780-7013Tel: 714.832.9922Fax: 714.832.9924Technical AssistanceTel: 800.366.3891 x73223Tel: 952.
About the ProductCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 1-3 DATA PORT CONFIGURATIONT1 transport provides for full-duplex trans
About the Product 1-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Unlike other Campus-RS products, the Campus-RS CSU/DS-1 and CSU/DS
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 2-1 2INSTALLING THEINTERFACE CARDYou can install the Campus-RS CSU/DS-1 and CSU/DSX-1 int
Installing the Interface Card 2-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Campus-RS CSU/DS-1 Interface Card DC Sealing CurrentTh
Installing the Interface CardCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 2-3 Campus-RS CSU/DSX-1 Interface Card Pin ReversalThe foll
Installing the Interface Card 2-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual CAMPUS-STAR INSTALLATIONThe following sections describ
Installing the Interface CardCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 2-5 1 Slide the card into the guide rails in the desired sl
ii Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Revision History of This User ManualTo acquire copies of this user manual, order docu
Installing the Interface Card 2-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Installing a Campus-RS Line Unit into a Campus-Star Ch
Installing the Interface CardCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 2-7 CAMPUS-RS DESKTOP UNIT INSTALLATIONThe following sectio
Installing the Interface Card 2-8 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Connecting a Campus-RS Desktop Unit to an HDSL LineTo
Installing the Interface CardCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 2-9 Cabling the Campus-RS CSU/DSX-1 Interface CardThe DSX-1
Installing the Interface Card 2-10 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-1 3CONFIGURING ANDMONITORING USINGLCD MENUSYou can configure the Campus-RS CSU/DS-1 and
Configuring and Monitoring Using LCD Menus 3-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual The following table describes how to use
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-3 6 Do one of the following:• Press Enter t
Configuring and Monitoring Using LCD Menus 3-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual CONFIGURING THE HDSL RATEThe Campus-RS CS
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-5 To set these options:1 Press Escape until
Using this ManualCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual iii USING THIS MANUALThis manual is organized as follows:• Chapter 1 d
Configuring and Monitoring Using LCD Menus 3-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Insert Framing is typically not required
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-7 Setting Channel BlockingYou can independe
Configuring and Monitoring Using LCD Menus 3-8 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Setting the Idle CodeWhen you choose to e
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-9 5 Do one of the following:• Press Enter t
Configuring and Monitoring Using LCD Menus 3-10 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4 Press Next until the desired setting d
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-11 CONFIGURING AS A MASTER OR SLAVE UNITThe
Configuring and Monitoring Using LCD Menus 3-12 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual MONITORING DS-1 OR DSX-1 LINE STATUSSeve
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-13 3 Press Enter to display the current ala
Configuring and Monitoring Using LCD Menus 3-14 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Configuring Alarm ThresholdsAlarm thresh
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-15 • Local errored seconds (LOCAL ES)• Remo
Document Conventions iv Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual DOCUMENT CONVENTIONSTwo types of messages, identified by icons,
Configuring and Monitoring Using LCD Menus 3-16 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Viewing and Configuring Local AlarmsLoss
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-17 Viewing and Configuring Remote AlarmsLos
Configuring and Monitoring Using LCD Menus 3-18 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual CONFIGURING LOOPBACKSLoopbacks provide a
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-19 3 Press Next to scroll through the loopb
Configuring and Monitoring Using LCD Menus 3-20 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Configuring the Response to External Loo
Configuring and Monitoring Using LCD MenusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3-21 You cannot change this information throu
Configuring and Monitoring Using LCD Menus 3-22 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-1 4CONFIGURING THROUGHTHE ASCII TERMINALYou can use an ASCII terminal or computer with
Configuring Through the ASCII Terminal 4-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual CONNECTING TO AN ASCII TERMINALTo connect the
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-3 3 Configure the ASCII terminal to the followi
Table of ContentsCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual v TABLE OF CONTENTSChapter 1: About the Product______________________
Configuring Through the ASCII Terminal 4-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Logging On a Local Campus UnitTo log onto a l
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-5 2 Press to log on. If you have changed the
Configuring Through the ASCII Terminal 4-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3 Press for Remote Logon, then press .The
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-7 Although the ASCII terminal is physically con
Configuring Through the ASCII Terminal 4-8 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual To set an option from a list of predefined va
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-9 1 At the Main Menu, type , then press to d
Configuring Through the ASCII Terminal 4-10 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3 Type , then press to restore the conf
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-11 3 Type , then press to toggle between the
Configuring Through the ASCII Terminal 4-12 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Set these options from the Data Port Setting
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-13 Inserting FramingWhen Insert Framing is on,
Table of Contents vi Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Setting the Framing Mode...
Configuring Through the ASCII Terminal 4-14 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Setting Channel BlockingYou can independentl
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-15 Setting the Idle CodeWhen you enable channel
Configuring Through the ASCII Terminal 4-16 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Setting the Line Build OutSet the Line Build
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-17 • If a unit is set to Master, it initiates t
Configuring Through the ASCII Terminal 4-18 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3 Type , then press . The Standard Mode HD
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-19 • Receiver (Rcv) Pulse Density Alarm is alwa
Configuring Through the ASCII Terminal 4-20 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 2 Type , then press to display the System
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-21 Configuring HDSL Margin Alarm ThresholdHDSL
Configuring Through the ASCII Terminal 4-22 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Setting Rcv Pulse Density AlarmThe Receive P
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-23 3 Type , then press to display the System
Table of ContentsCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual vii Restoring the System to Default Values...
Configuring Through the ASCII Terminal 4-24 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4 Continue with the following sections to se
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-25 Changing a PasswordA password prevents unaut
Configuring Through the ASCII Terminal 4-26 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5 Type a unique identifier for the circuit.
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-27 1 At the Main Menu, type , then press to
Configuring Through the ASCII Terminal 4-28 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Initiating a Loopback1 At the Loopback Setti
Configuring Through the ASCII TerminalCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4-29 1 At the Loopback Settings Menu, type , the
Configuring Through the ASCII Terminal 4-30 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 3 Type , then press . The available Extern
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-1 5USING AN ASCII TERMINALTO VIEW INFORMATIONAND STATUSThis chapter describes how to us
Using an ASCII Terminal to View Information and Status 5-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual MONITORING HDSL PERFORMANCETh
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-3 The Current System Status scr
Table of Contents viii Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Chapter 5: Using an ASCII Terminal to View Informationand Status
Using an ASCII Terminal to View Information and Status 5-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 4 The information on the Curr
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-5 The 24 Hour HDSL Performance
Using an ASCII Terminal to View Information and Status 5-6 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Viewing Seven-Day HDSL Perfor
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-7 MONITORING DATA PORT PERFORMA
Using an ASCII Terminal to View Information and Status 5-8 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 2 Type , then press . The I
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-9 The following table describes
Using an ASCII Terminal to View Information and Status 5-10 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Viewing 24-Hour Data Port Pe
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-11 Viewing 7-Day Data Port Perf
Using an ASCII Terminal to View Information and Status 5-12 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual VIEWING RECEIVE CHANNEL SIGN
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-13 2 Type , then press to di
Table of ContentsCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual ix Remote to Local Loopbacks...
Using an ASCII Terminal to View Information and Status 5-14 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual VIEWING PERFORMANCE REPORT M
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-15 This screen displays the fol
Using an ASCII Terminal to View Information and Status 5-16 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual VIEWING LOCAL ALARM HISTORYT
Using an ASCII Terminal to View Information and StatusCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 5-17 VIEWING PRODUCT INFORMATIONT
Using an ASCII Terminal to View Information and Status 5-18 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Jun 26, 1999 PAIRGAIN TECHNO
Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 6-1 6TESTING THE SYSTEMUSING LOOPBACK TESTSThe Campus-RS CSU/DS-1 and CSU/DSX-1 Interface
Testing the System Using Loopback Tests 6-2 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual The following loopback tests are supported:•
Testing the System Using Loopback TestsCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 6-3 Remote to Local LoopbackThe Remote to Local
Testing the System Using Loopback Tests 6-4 Campus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual Clearing Loopbacks ManuallyYou can clear a l
Testing the System Using Loopback TestsCampus-RS CSU/DS-1 and CSU/DSX-1 Interface Cards User Manual 6-5 Data link (out of band) loop codes are valid
Comments to this Manuals