ADC AD-200 Service Manual Page 100

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 99
96
NOTE: SPRINKLER MUST HAVE POWER FOR THE DRYER TO OPERATE.
B. Drive motor is not operating (does not start)...
* Microprocessor controller (computer) relay output indicator (either forward “FWD” or reverse
“REV”) is on.
1. Blown drive motor contactor overloads.
2. Failed drive motor contactor.
3. Failed drive motor.
4. No 24 VAC present at drive motor contactor coil.
* Microprocessor controller (computer) relay output indicator (neither forward “FWD” nor reverse
“REV”) is on.
1. Failed microprocessor controller (computer) input/output (I/O) board.
C. Drive motor operates in one (1) direction ONLY...stops and restarts in the same direction...
* Appropriate microprocessor controller (computer) relay output indicator is on.
1. Failed reversing contactor (relay).
2. Failed electrical reversing contactor interlock.
* Appropriate microprocessor controller (computer) relay output indicator is off.
1. Failed microprocessor controller (computer) I/O board.
D. Drive motor operates okay for a few minutes and then either repeatedly or occasionally trips
the overload protector...
NOTE: When the overload protector trips, the microprocessor controller (computer) I/O board, “red”
light emitting diode (L.E.D.) “TBOL” will be off and the display will read “Tumbler Overload
Fault.”
1. Motor is overheating...
a. Motor air vents clogged with lint.
b. Low voltage to motor.
c. Failed motor.
d. Basket (tumbler) is binding...check for an obstruction.
e. Basket (tumbler) bearings are binding.
Page view 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 106

Comments to this Manuals

No comments