Page view 78
MYXPM6021*
Revision 1.1 - 10/21/14
*Advanced information. Subject to change without notice.
79
MYXPM6021*
Form #: CSI-D-685 Document 011
• VBATRM–MYXPM6021detectsthatabatterywasremovedfromthesystembyVBATcomparatorwhenthebit
BATRMSRCinthePSDETCTRLregisteriscleared(=0).
Criticaleventsare:
• IDBATRM–MYXPM6021detectsthatabatterywasremovedfromthesystembyBATIDpresencecomparator
whenthebitBATRMSRCinthePSDETCTRLregisterisset(=1).AllVRsareshutdowninsequencedorderbut
withoutwaitingforSLP_S*_BfromSOC.
• BCUVCRIT–TheBCUdetectsthattheVSYSvoltagenodehasenteredthe“VCRIT”operatingzone.