ADC AD-25 Installation Manual

Browse online or download Installation Manual for Electric laundry dryers ADC AD-25. ADC AD-25 Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 61
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
For replacement parts, contact the reseller from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
www.amdry.com
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Ne pas tenter d’allumer d’appareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez.
* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
AD-25/AD-30/AD-50
(Std. Phase 7 OPL/FSS/HSI)
Installation Manual
083001JEV/mcronan ADC Part No. 113336
Page view 0
1 2 3 4 5 6 ... 60 61

Summary of Contents

Page 1 - Installation Manual

For replacement parts, contact the reseller from which the dryerwas purchased orAmerican Dryer Corporation88 Currant RoadFall River MA 02720-4781Telep

Page 2 - Important

6SECTION IISPECIFICATIONSA. SPECIFICATIONS (AD-25)* Contact factory for information not listed, 3-phase (3ø) figures shown are for 3-wire service, no

Page 3 - FOR YOUR SAFETY

7GasElectricSteam** MAXIMUM CAPACITY (DRY WEIGHT) 30 lbs 13.6 kg BASKET (TUMBLER) DIAMETER 30” 76.2 cm BASKET (TUMBLER) DEPTH 30” 76.2 cm BASKET (TUMB

Page 4

8C. SPECIFICATIONS (AD-50)* 50 lbs (22.7 kg) reversing dryer available with 3-phase (3ø) motors standard with 1/2 HP (0.37 kw) motors.** Size of pipi

Page 5 - Table of Contents

9SpecificationsADG-25 (Gas)ADE-25 (Electric)ADS-25 (Steam)NOTE: ADC reserves the right to make changes in specifications at any time without notice or

Page 6

10NOTE: ADC reserves the right to make changes in specifications at any time without notice orobligation.SpecificationsADG-30ADE-30ADS-30

Page 7 - SECTION I

11SpecificationsADG-50ADE-50ADS-50NOTE: ADC reserves the right to make changes in specifications at any time without notice orobligation.

Page 8 - B. SAFETY PRECAUTIONS

12SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state codes. In theabsence

Page 9

13B. LOCATION REQUIREMENTSBefore installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of suchcodes or o

Page 10 - SECTION II

14C. DRYER ENCLOSURE REQUIREMENTSBulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.4

Page 11 - ElectricSteam**

15D. FRESH AIR SUPPLY REQUIREMENTSThe fresh air supply (make-up air) must be given careful consideration to assure proper performance of eachdryer.

Page 12 - GasElectricSteam****

Retain This Manual In A Safe Place For Future ReferenceAmerican Dryer Corporation products embody advanced concepts in engineering, design, and safety

Page 13 - ADE-25 (Electric)

16E. EXHAUST REQUIREMENTSExhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork willcreate excessi

Page 14

17SINGLE DRYER VENTINGIMPORTANT: For exhaust duct runs over 30 feet (9.14 meters) a minimum size of 10-inches (25.4cm) must be used.HORIZONTAL VENTING

Page 15

18VERTICAL VENTINGWhen vertical single venting is used, the minimum duct size is 10-inches (25.4 cm) refer to Illus. B below, theductwork from the dry

Page 16 - SECTION III

19MULTIPLE DRYER (COMMON) VENTINGHORIZONTAL VENTINGIf it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers

Page 17 - B. LOCATION REQUIREMENTS

20IMPORTANT: For extended ductwork runs, the cross-section area of the duct can only be increasedto an extent. For extended ductwork runs, a professi

Page 18

21IMPORTANT VENTING REMINDERS1. Ductwork size and installation should be done by a qualified professional.2. The dryer must be exhausted to the outdoo

Page 19

22F. ELECTRICAL INFORMATION1. Electrical RequirementsIt is your responsibility to have ALL electrical connections made by a properly licensed and com

Page 20 - E. EXHAUST REQUIREMENTS

232) Electric Models ONLYALL electrically heated dryers must be connected to the electric service shown on the dryer’sdata label, which is affixed to

Page 21 - SINGLE DRYER VENTING

24If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed powercord or pigtail (wire size must conform to rating of

Page 22 - Illus. B

255. 3-Phase (3ø) Wiring Connections/HookupThe only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, andsometim

Page 23 - Illus. C

IMPORTANTYOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GASSUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS AREREMOVED FROM THE MAC

Page 24 - Illus. D

26CAUTION: The dryer must be grounded. A ground lug has been provided for this purpose.IMPORTANT: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.The

Page 25 - IMPORTANT VENTING REMINDERS

27IMPORTANT: The dryer must be connected to the electric supply shown on the data label that isaffixed to the left side panel/wall area behind the con

Page 26 - F. ELECTRICAL INFORMATION

28ADG-30 (GAS)ADS-30 (STEAM)ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)IMPORTANT:NOTES: A. B. C.208 VAC AND 240 VAC ARE NOT THE SAME. When orderi

Page 27

29ADG-50 Non-Reversing (Gas)ADS-50 Non-Reversing (Steam)ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: NOTES: A. B. C.208 VAC and 240 VA

Page 28

30AD-50 Reversing (Gas)AD-50 Reversing (Steam)ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: NOTES: A. B. C.208 VAC AND 240 VAC ARE NOT THE

Page 29

31G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gasplumbing instal

Page 30

322. Technical Gas Dataa. Gas Specificationsb. Gas ConnectionsInlet connection -------------1/2-inch N.P.T.Inlet supply size -------------1/2-inch N.P

Page 31 - ADS-25 (STEAM)

333. Piping ConnectionsALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATESTEDITION, or in Canada, CAN/CGA

Page 32 - ADS-30 (STEAM)

34Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.05mm) pipe gas loop be installed in the supply l

Page 33

35H. STEAM INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gasplumbing inst

Page 34 - AD-50 Reversing (Steam)

WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY OR FIRE COULD RESULT.IMPOR

Page 35 - G. GAS INFORMATION

36a. The pressure of the condensate in the steam supply will cause water hammer and subsequent heatexchanger (steam coil) failure. The steam supply c

Page 36 - NATURAL LIQUID PROPANE

375. Steam Damper Air System ConnectionsThe ADS-30 is manufactured with a pneumatic (piston) damper system, which requires an external supplyof compre

Page 37

386. Steam Damper System OperationThe steam damper, as shown in the illustration below, allows the coil to stay constantly charged eliminatingrepeated

Page 38

397. Steam Damper Air Piston (Flow Control) Operation AdjustmentDamper operation was tested and adjusted prior to shipping at 80 PSI (5.51 bars). If

Page 39 - OPERATING STEAM PRESSURE

40I. PREPARATION FOR OPERATION/START-UPThe following items should be checked before attempting to operate the dryer:1. Read ALL “CAUTION,” “WARNING,”

Page 40

41J. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational testshould be performe

Page 41 - AIR PRESSURE

425. Make a complete operational check of ALL operating controls.NOTE: If computer program changes are required, refer to the computer programming sec

Page 42 - Diagram 2

43NOTES: 1. If the Anti-Wrinkle program is active, the light emitting diode (L.E.D.) display will continueto read “donE,” and the microprocessor contr

Page 43

44b. Select temperature...The dryer will start, the light emitting diode (L.E.D.) display will read the temperature cycle selected,and the drying time

Page 44

452) Press the “E” on the keyboard (touch pad).3) The light emitting diode (L.E.D.) display will quickly show cycle selected and the dryer will start.

Page 45 - J. PREOPERATIONAL TESTS

Table of ContentsSECTION IIMPORTANT INFORMATION...3A. Receiving and Handling ..

Page 46 - COIN MODELS

46SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If s

Page 47

47SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARDS1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back

Page 48 - OPL MODELS

482. Each part must be tagged with the following information:a. Model number and serial number of the dryer from which part was removed.b. Nature of f

Page 49 - L. SHUT DOWN INSTRUCTIONS

49SECTION VIROUTINE MAINTENANCEA. CLEANINGA program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from

Page 50 - SECTION IV

50WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straightenby using a fin comb, which is available from l

Page 51 - SECTION V

51SECTION VIIDATA LABEL INFORMATIONA. DATA LABELContact American Dryer CorporationWhen contacting American Dryer Corporation certain information is r

Page 52

52THE DATA LABEL1. MODEL NUMBERThe model number is an ADC number, which describes the size of the dryer and thetype of heat (gas, electric, or steam).

Page 53 - SECTION VI

53SECTION VIIIREVERSING TIMER SPIN/DWELL ADJUSTMENTSDual timer models with “reversing option” have an electric reversing timer in the electric service

Page 54 - C. LUBRICATION

54SECTION IXPROCEDURE FOR FUNCTIONAL CHECKOF REPLACEMENT COMPONENTS1. Microprocessor Controller (Computer) Boarda. Upon completing installation of the

Page 55 - SECTION VII

552. For Models With Hot Surface Ignition (HSI) Module (CE Version)a. Upon completing installation of the replacement HSI module, reestablish power to

Page 56

SECTION VIROUTINE MAINTENANCE ...49A. Cleaning ...

Page 57 - SECTION VIII

56 IMPORTANT This dryer is equipped with a burner hi-limit and tumbler/lint chamber hi-limit thermostat which must be

Page 58 - SECTION IX

ADC 113336 1 - 09/10/01-500 2* 09/20/01-500

Page 59

3SECTION IIMPORTANT INFORMATIONA. RECEIVING AND HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners and

Page 60 - I M P O R T A N T

4B. SAFETY PRECAUTIONSWARNING: For your safety, the information in this manual must be followed to minimize the risk offire or explosion or to preven

Page 61

5WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create afire hazard.WARNING: DO NOT use heat for drying articles that

Comments to this Manuals

No comments