Page 1 - USER MANUAL

USER MANUALSoneplexDS3 Loop Extender (D3LX) CO Module Product: D3LXC-FCA100, D3LXC-SCA100CLEI Code: SOCPG2GB, SOCPG2KBSoneplexDS3 Loop Extender (D3LX)

Page 2 - Related Documentation

Overview LTPS-UM-8013-032 August 30, 2002 D3LX CO and RMT ModulesFigure 2. System Overview D3LX CO2 3 4 5 6 7 56 4 3 2 119 18 17 16 1520 21 2016 17

Page 3 - INSPECTING SHIPMENT

LTPS-UM-8013-03 Front-Panel DescriptionD3LX CO and RMT Modules August 30, 2002 3FRONT-PANEL DESCRIPTIONFigure 3 shows the D3LX CO front panel. Table

Page 4

Front-Panel Description LTPS-UM-8013-034 August 30, 2002 D3LX CO and RMT ModulesPROTECTION SWITCHINGThe D3LX system may be configured for either p

Page 5 - TABLE OF CONTENTS

LTPS-UM-8013-03 Front-Panel DescriptionD3LX CO and RMT Modules August 30, 2002 5Automatic SwitchingThe 1:1 (Line) Protect mode transmits identical t

Page 6

Preparing to Install D3LX Modules LTPS-UM-8013-036 August 30, 2002 D3LX CO and RMT ModulesPREPARING TO INSTALL D3LX MODULESPrior to installing D3L

Page 7 - LIST OF FIGURES

LTPS-UM-8013-03 Installing the BNC PanelD3LX CO and RMT Modules August 30, 2002 7INSTALLING THE BNC PANELOVERVIEWThe ADC BNC Panel consists of 14 p

Page 8 - LIST OF TABLES

Installing the BNC Panel LTPS-UM-8013-038 August 30, 2002 D3LX CO and RMT Modules6 From the rear of the panel, connect the coax end of an ADC adap

Page 9 - OVERVIEW

LTPS-UM-8013-03 Installing a D3LX CO Module in an LECD3LX CO and RMT Modules August 30, 2002 9INSTALLING A D3LX CO MODULE IN AN LECUse the followin

Page 10 - CO - Local

Installing a D3LX CO Module in an LEC LTPS-UM-8013-0310 August 30, 2002 D3LX CO and RMT ModulesFigure 5. Routing the Fiber Patch Cord4 Locate the

Page 11 - FRONT-PANEL DESCRIPTION

LTPS-UM-8013-03 Installing a D3LX CO Module in an LECD3LX CO and RMT Modules August 30, 2002 11Figure 6. D3LX Module Locations in Loop Extender Cha

Page 12 - PROTECTION SWITCHING

LTPS-UM-8013-03ii August 30, 2002 D3LX CO and RMT ModulesRevision History of This ManualTo order copies of this document, use document catalog numb

Page 13 - APPLICATIONS

Installing a D3LX CO Module in an LEC LTPS-UM-8013-0312 August 30, 2002 D3LX CO and RMT ModulesFigure 7. Installing the D3LX CO9 After removing th

Page 14

LTPS-UM-8013-03 Installing a D3LX CO Module in an LECD3LX CO and RMT Modules August 30, 2002 13Verification of D3LX CO Optical Power 1 Connect an a

Page 15 - INSTALLING THE BNC PANEL

Installing a D3LX RMT Module in a Remote Cabinet LTPS-UM-8013-0314 August 30, 2002 D3LX CO and RMT ModulesINSTALLING A D3LX RMT MODULE IN A REMOTE

Page 16

LTPS-UM-8013-03 Installing a D3LX RMT Module in a Remote CabinetD3LX CO and RMT Modules August 30, 2002 153 Locate the mounting slots designated fo

Page 17

Installing a D3LX RMT Module in a Remote Cabinet LTPS-UM-8013-0316 August 30, 2002 D3LX CO and RMT ModulesTWO-POSITION QLX REMOTE BNC CHASSIS INST

Page 18 - Fiber patch cord

LTPS-UM-8013-03 Installing a D3LX RMT Module in a Remote CabinetD3LX CO and RMT Modules August 30, 2002 17Verification of Optical Power 1 Connect a

Page 19 - DS3 ONLINE

Provisioning LTPS-UM-8013-0318 August 30, 2002 D3LX CO and RMT Modules15 Store the remaining slack fiber on the left side of the fiber management e

Page 20 - POWER VERIFICATION

LTPS-UM-8013-03 Setting Up System OptionsD3LX CO and RMT Modules August 30, 2002 19OTHER PROVISIONING CONSIDERATIONSAlarm Setting During Provisioni

Page 21

Setting Up System Options LTPS-UM-8013-0320 August 30, 2002 D3LX CO and RMT Modules• 9600 baud • No parity• 8 data bits• 1 stop bit• Hardware flow

Page 22 - REMOTE CABINET

LTPS-UM-8013-03 Setting Up System OptionsD3LX CO and RMT Modules August 30, 2002 215 At the maintenance terminal, press . The Enter User Name fiel

Page 23 - 2-1 2-31-3

LTPS-UM-8013-03 Using This ManualD3LX CO and RMT Modules August 30, 2002 iiiUSING THIS MANUALThe following conventions are used in this manual:• Mon

Page 24

Setting Up System Options LTPS-UM-8013-0322 August 30, 2002 D3LX CO and RMT ModulesNAVIGATING THROUGH CRAFT INTERFACE MENUSMany of the operations

Page 25

LTPS-UM-8013-03 Local ConfigurationD3LX CO and RMT Modules August 30, 2002 23LOCAL CONFIGURATIONA D3LX system can be configured locally by an SCU (v

Page 26 - PROVISIONING

Local Configuration LTPS-UM-8013-0324 August 30, 2002 D3LX CO and RMT Modules4 Configure the fields as detailed in the Table 5 and assign the sele

Page 27 - SETTING UP SYSTEM OPTIONS

LTPS-UM-8013-03 Local ConfigurationD3LX CO and RMT Modules August 30, 2002 25CONFIGURING D3LX ALARMSUse this procedure to set alarm indicators for e

Page 28 - Craft port

Local Configuration LTPS-UM-8013-0326 August 30, 2002 D3LX CO and RMT ModulesFigure 14. D3LX Alarm Setting MenuTable 6. D3LX Alarm Level DefaultsC

Page 29 - Interface cable

LTPS-UM-8013-03 Local ConfigurationD3LX CO and RMT Modules August 30, 2002 27DISPLAYING D3LX STATUSUse this procedure to display the status of both

Page 30

Local Configuration LTPS-UM-8013-0328 August 30, 2002 D3LX CO and RMT ModulesVIEWING LOOPBACK STATUS AND PERFORMING LOOPBACK COMMANDSUse this proc

Page 31 - LOCAL CONFIGURATION

LTPS-UM-8013-03 Local ConfigurationD3LX CO and RMT Modules August 30, 2002 29PERFORMANCE MONITORINGUse this procedure to monitor the performance of

Page 32

Local Configuration LTPS-UM-8013-0330 August 30, 2002 D3LX CO and RMT ModulesPERFORMING SYSTEM MAINTENANCEUse this procedure to perform the system

Page 33 - CONFIGURING D3LX ALARMS

LTPS-UM-8013-03 Local ConfigurationD3LX CO and RMT Modules August 30, 2002 31Figure 18. System Maintenance–Trouble Isolation Screen ShownLOGGING OFF

Page 34

Inspecting Shipment LTPS-UM-8013-03iv August 30, 2002 D3LX CO and RMT Modules

Page 35 - DISPLAYING D3LX STATUS

Local Configuration LTPS-UM-8013-0332 August 30, 2002 D3LX CO and RMT ModulesREMOVING D3LX MODULESFigure 19. Removing a D3LX Module–D3LX CO Shown1

Page 36 - LOOPBACK COMMANDS

LTPS-UM-8013-03 Remote ConfigurationD3LX CO and RMT Modules August 30, 2002 33REMOTE CONFIGURATIONUse the D3RCAM craft interface system menu to view

Page 37 - PERFORMANCE MONITORING

Remote Configuration LTPS-UM-8013-0334 August 30, 2002 D3LX CO and RMT ModulesD3RCAM MENUThe D3RCAM Main Menu (as shown in Figure 21) displays fol

Page 38 - PERFORMING SYSTEM MAINTENANCE

LTPS-UM-8013-03 Remote ConfigurationD3LX CO and RMT Modules August 30, 2002 351 From the Main menu, select 3. Unit Configuration.2 Within the Unit C

Page 39 - LOGGING OFF

Troubleshooting LTPS-UM-8013-0336 August 30, 2002 D3LX CO and RMT ModulesTROUBLESHOOTINGBefore the system tests are started, the fiber-optic networ

Page 40 - REMOVING D3LX MODULES

LTPS-UM-8013-03 Appendix A - SpecificationsD3LX CO and RMT Modules August 30, 2002 37APPENDIX A - SPECIFICATIONS Table 9. D3LX Module Specification

Page 41 - REMOTE CONFIGURATION

Appendix A - Specifications LTPS-UM-8013-0338 August 30, 2002 D3LX CO and RMT ModulesD3LX CARD-EDGE CONNECTORFigure 23 shows the pin assignments o

Page 42 - UNIT CONFIGURATION

LTPS-UM-8013-03 Appendix B - Cleaning and Mating Fiber-Optic SystemsD3LX CO and RMT Modules August 30, 2002 39APPENDIX B - CLEANING AND MATING FIBE

Page 43

Appendix B - Cleaning and Mating Fiber-Optic Systems LTPS-UM-8013-0340 August 30, 2002 D3LX CO and RMT ModulesMATINGMate the SC and FC connectors

Page 44 - TROUBLESHOOTING

LTPS-UM-8013-03 Appendix C - Product SupportD3LX CO and RMT Modules August 30, 2002 41APPENDIX C - PRODUCT SUPPORTADC Customer Service Group provid

Page 45 - APPENDIX A - SPECIFICATIONS

LTPS-UM-8013-03 Table of ContentsD3LX CO and RMT Modules August 30, 2002 vTABLE OF CONTENTSOverview ________________________________________________

Page 46 - D3LX CARD-EDGE CONNECTOR

Appendix D - Abbreviations LTPS-UM-8013-0342 August 30, 2002 D3LX CO and RMT ModulesAPPENDIX D - ABBREVIATIONSAAPS: Automatic Protection Switchin

Page 47 - FIBER-OPTIC SYSTEMS

CERTIFICATION AND WARRANTYFCC CLASS A COMPLIANCEThis equipment has been tested and found to comply with the limits for a Class A digital device, purs

Page 48

ADC DSL Systems, Inc.14402 Franklin AvenueTustin, CA 92780-7013Tel: 714.832.9922Fax: 714.832.9924Technical AssistanceTel: 800.366.3891 x73223Fax: 952.

Page 49 - APPENDIX C - PRODUCT SUPPORT

Table of Contents LTPS-UM-8013-03vi August 30, 2002 D3LX CO and RMT ModulesPerformance Monitoring ...

Page 50 - APPENDIX D - ABBREVIATIONS

LTPS-UM-8013-03 List of FiguresD3LX CO and RMT Modules August 30, 2002 viiLIST OF FIGURES1. D3LX CO and D3LX RMT Modules...

Page 51 - CERTIFICATION AND WARRANTY

List of Tables LTPS-UM-8013-03viii August 30, 2002 D3LX CO and RMT ModulesLIST OF TABLES1. D3LX Front-Panel Description and Status LEDs ...

Page 52 - DOCUMENT: LTPS-UM-8013-03

LTPS-UM-8013-03 OverviewD3LX CO and RMT Modules August 30, 2002 1OVERVIEWThe Soneplex® DS3 Loop Extender (D3LX) modules shown in Figure 1 are a pair

Comments to this Manuals

No comments