We reserve the right to alter design and range of our products without prior notice | Kabeldon low voltage switchgear system 2011 | 5
Fundamental technologies
We work on the basis of four fundamental technologies
within which we have accumulated substantial expertise over
many years.
Electrical connections
The safe and secure transfer of electric current between
cable conductors, or between a cable conductor and a
device, requires an electrical connection of good quality.
We test and develop various methods, but in most cases we
use bolt technology, that gives us the possibility of offering
complete solutions in line with our philosophy of easy and
safe installation.
Controlling electrical fields
At high voltages the electrical fields must be controlled
so that the str
ength of the insulation or the surrounding
material is not put at risk. Depending on the voltage level, we
work with different methods, e.g. geometrical, refractive or
resistive field
control.
Geometrical field control is achieved with premoulded stress
cones and splicing blocks.
Resistive and refractive field control are achieved with
special field controlling materials integrated into premolded
termination blocks.
Development of creepage current resistant materials
Outdoors, cable accessories are exposed to major stresses,
e.g. UV radiation fr
om the sun and creepage currents
caused by precipitation and pollution. Cable accessories
are installed everywhere on the face of the planet: in humid
tropical environments, in extreme cold or in the swirling salt
mist of coastal regions. We develop materials and designs
for outdoor use that are only minimally affected by external
factors. In the case of cable terminations, it is the insulators,
both in porcelain and composite material. Practical
endurance tests are an important part of our development
work. In addition to Weather-O-Meter, salt-mist-chamber
tests and other destructive long-term tests, the products are
tested under outdoor weather conditions.
Design of low voltage networks
Electrical distribution in power cable networks calls for safe
and rugged pr
oducts to connect cables and to withstand
external factors such as humidity, vibration, etc., for a long
time without causing malfunctions.
Lengthy experience of our own manufacture of switching
devices and hot-dip galvanized enclosures, as well as good
customer relations, means that we can quickly adapt product
development to suit the needs of the market.